Untwist wires and relight pilot. As for Kenmore and Sears they would send a replacement part our for $185.00 and 2-5 days delivery or since the part is under warranty I could pay $79.00 and wait for a service appointment, then wait for the replacement part to be shipped for me to install. The Water heater will appear to be working now, but in a several seconds it will figure out that something is wrong, and it will shutdown the pilot valve and the fire will shut off. So I changed that out for a 1/4 turn one, much easier. Bam! My Whirlpool gas water heater is giving me the dreaded four blinks signal. The WT8840 Water Heater Control is designed for use, in Standing Pilot applications using an immersion, well for water temperature sensing. Suggestions? So that is an option for those that want one straight away in town, or they will reimburse you. Resideo WT8840B1500 - WT8840 Water Heater Gas Valve Control, NG - 2" Spud, 5" W.C.- WATER HEATER GAS VALVE, STANDING PILOT WITH PIEZO, SETPOINT 55-155F, SPUD LENGTH = 2", BRACKET= CENTERED, REGULATOR SETTING= 5" W.C., GAS TYPE=NATURAL GAS <br><br> The WT8840 series is the Water Heater Control for trade use to replace WV8840 valves used in AO Smith and Bradford White Water Heaters. After the pilot heats the thermopile, and the LED blinks, I released the Red knob but the pilot would not stay on. Ignite pilot then rotate to hot. : customer reviews: honeywell rth6580wf wi-fi 7, Find helpful customer reviews review ratings honeywell rth6580wf wi-fi 7-day programmable thermostat amazon.. read honest unbiased product reviews. I did order free replacement the part and went for the free ground ship to Calif as well as i had faith in you guys thatthe tips would work before the part got here. If it does not start up on its own after the shutdown, then you may have to reconnect the battery to the right top pin and go through the above procedure again and it will shutdown again. That SHOULD simply cause the heat source to have to stay on longer to heat water, not get the water too hot; 3. My model doesnt have a pilot that is lit and stays on all of the time, but rather an electronic ignitor. The valve is known to be defective and maybe they will help ? The water heater would not work properly right out of the box. Thanks. Gas and Flame Detection. Im keeping your method in my hip pocket, though, because it is much simpler. Taking out the circuit board and shorting across the pins (on back side of board) of what I believe is a capacitor**, worked to get the 7 flashes and then unit would light. At this point mine lit the main burner and blinked 7 a few times then blinked 1 1 1 1. I finally decided I would remove the burner unit & giveit a thorough cleaning (blow, brush & vacuum the screen) in the morning. Im assuming that the old board just completely died. I will miss 7 -10 years of worry free There is no pilot, it just ignites completely as needed with electronic ignitor. Ive been reading the above posts with great interest. I have advised my friends to call and tell them they have four flashes and get the gas valve now whether or not it has died. Tonight I came home to the 4 blink code again No problem Ill just reset it one more time to get us through showers tonight and replace it tomorrow. While you have the old valve out, be sure to probe inside to see if you have gunk/sediment and/or crystals/salts. Thank you Pioneers, Thank you Tyler. Thanks that was a big help and a $$ saver. I have not touched mine in any way, just been doing watchful observation until I have (and now do have) new valve in hand. No, No, No! My install is brand new, so there is no connection to any sediment buildup causing any malfunction state. Last year the Pilot light kept going out by itself. and now I got myself a huge repair issue, what the hell is wrong with kenmore and Honeywell to make a dial that allows you to raise the temp up to A,B,C AND VERY HOT and just by putting it up to A now I get 4 blinking lights and have to pay a repair technician to come give me a diagnostic! Some of us had moved the controller dial through its full range and subsequently the controller failed with the 4 code. Honeywell stinks & has caused lots of trouble for me. Worked like a charm with an old AA battery & a couple of bread ties, thanks for for sharing the knowledge! The thermal switch on the hot water heater was broken. I suspect that shorting the posts is the way the Sears tech did it the first time. This worked for me! I was reading how you guys help one another and just thought AWESOME! But, the light on the control never starts flashing. Awesome articles you post on your blog, i have shared this article on my facebook. Thanks E. Update : Tried all the reset methods and none worked for me for the white light control valve. No lights at all this time I couldnt even get it to do any lights when trying to light the pilot light. Pilot light will come on but wont stay on after releasing the button. Only 1 day without hot water thanks to you. I too thought no big deal to turn my water heater up ONE NOTCH!!! Turned the dial to low and it started heating. Also, the white light version has NO COM connector. Its two pins go through the board. WV4262E1107 it has a much larger board and connects a bit different. Chapters Replacing Honeywell WV8840B1042 WV8840B1109 WV8840B1110 with WT8840B1000 5 flash blink error problem Nathan LeMarbe 592 subscribers Subscribe 4.7K views 2 years ago Just finished. Called Whirlpool, got the run-around everyone else is getting, called a few plumbers who were all in the $150+/hour. . I have the 50 gallon model of the Whirlpool water heater from Lowes that has the Honeywell controller on a Bradford White valve. If you need to, stick the screwdriver in from below to lever them loose. worked for me. Cal. Let me step in line with all of you. Do not loose the spring under it! Because of these differences, I would recommend NOT to only replace the board, but to replace everything! Hey just wanted to say a BIG thank you to you guys for the reboot reset tips the jumper wire to all points worked best for me! This would do the same as pulling the connector off the board and relighting the pilot momentarily. Okay. Well, tried this with TWO circuit boards (one was original w/red LED, the second was replacement w/white LED). Should save this to a word fileBut hopefully I wont ever need them again..My water heater is 2 years old and has a 6 year warranty on parts..I called Monday morning and spoke to a Johnathon (real nice fella) and he shipped me the whole thermostat assembly. He gave me the $30 overnight speech but I opted for the $10 and some change shippingGot it 2 days later! CORRECTING LAST SENTENCE: main valve (Right pin to (+), So I would recommend to you ( with Valve off the water heater and no gas applied, to test the pilot valve (left pin to (+))with the AA battery, and test the main valve (Right pin to (+)), and each individually should click, photo of pilot valve solenoid Basically the Honeywell Electronic Gas Water Heater Controllers are crap (so far). Although the reset procedures in this thread are obviously great and simple workarounds to the problem of resetting this damn valve, I also wonder if there may be some secondary interlock linked to the gas pressure which would cause the valve to retain an error condition as long as it is detecting gas pressure? Great just what I needed, obviously the plumber who installed the WH did not change the 30 yr old shut off valve at the same time! Honeywell Wv8840B1158 Manual. When I contacted Rheem again, without hesitation they said they were Fed-Exing me a new valve. Like theyre doing me a favor even though I reminded them that it has a 12 year warranty on parts. I had to pay $30 overnight shipping. First, do NOT buy any water heater with this type of controller (you can zoom in on the ad pic. Just install the board with the cover removed as outlined. The next guy I talked to was very surprised that the Valve would be bad again so quickly so he had me go through a reset procedure. Basically, the minerals heat less efficiently than the water, so the water has to get hotter than necessary. I just duplicated the steps that Charles on 29 July, 2014 took. God Bless you! My tank is fed solar preheated water, and so far, that water has been warm enough that the main propane burner has never fired with the thermostat set to LOW, so I was just curious. If that didnt work, or if you already have the new valve and prefer the slightly simpler approach, proceed as follows. light the pilot and you still get the 7 flashes; however the water heater kicks back on and gets back up to temperature and shuts off as normal and you will see that your light now only flashes 1 time every 3 or 4 seconds. Would appreciate any info on fixing the WHITE Light Gas valve. As info only for the less mechanical people out there, if you lay down on your back and look through the sight glass window, it makes lighting your pilot very easy. Be gentle; its only plastic. It is also an adjustable regulator that insures proper gas pressure for combustion. honeywell wv8840b1109 manual honeywell wv8840b1109 manual Pmi reliance supply electric power partcrib please. Water Heater Gas Valve Replaces Honeywell Resideo WV8840B1109 WV8840B1110 WV8840B1109 WV8840B1110 Furnace Heater Gas Valve Shut-off Slow Fast Opening Pilot Spark Hot Surface Ignition Repair Part . Forgot to add one more important bit of informationI do not have any error codes, the red light blinks for standby mode and shows a heartbeat while the pilot light is on and continues despite the burner failing to ignite. They could not find that in their records. Important to note, new wires were different colors! Direct Replacement: Gas Control Valve Kit (Natural Gas) Brand: AO Smith SKU: 100112336 ( 70) In Stock Get 297 Fri, Mar 3 Order by today, receive 297 by Friday VIEW REPLACEMENT Product Highlights - Natural Gas Description - Hope this information helps! You can get the pilot to light by pressing this button, but unless you address the underlying problem, the chamber will overheat and the breaker will trip again. reattach the front cover with the wires still unplugged and light your pilot. Is the designer still alive? Within a couple minutes it reverted to 1 flash, and is working fine. This procedure worked like a charm. It refused to even start. At least it works again and Ill have the replacement ready if it ever fails again. I found the most reliable one is to install the parts without the cover and short the top two pins that go to the pilot light (left) and the main burner (right) and running it for a while. detected: When this happens after the four flashes, it seems like this is saying something like, There has been a fault detected, and there is no fault any more. In other words, there was a fault and it went away. Also had flushed out the tank. Cold water for 3 days in winter. And Im paying $30 for a part I shouldnt be replacing? I am now one of the afflicted and would not like to have to go through this every 18 months. I replace the whole unit and can not get the pilot to re-light. I cant believe they sent me a dud. This crap adds $15,000+ to our new automobiles. is there a small battery? I suspect it to be calcium and salts. The previous water-heater was never flushed in its 20 year life (the tank started leaking). All models of, WT8840 include an integrated NTC temperature, The WT8840 is powered from a thermopile heated by, the standing pilot flame. Followed your procedure to a T. I called GE because Honeywell said to. Had to do it twice for it to reset. The two 10 inch jumpers wrapped around the left and right pins was the method that worked for me. I, too, experienced the dreaded 4-flash-of-death failure after about 8 months of use, was given the replacement valve, did the complete flush of the tank only to discover no sediment issues and, as with most of the rest of you, received a valve with a different color indicator light. Mine is the 1109 and has no posts. I even suspect there is a simpler method to do it than the one Ill now detail. My house is going into escrow and it worked on my red light control board and saved me from buying a new control board or WH! faile, hot water thermostat is not cutting off at preset, My water heater has a Honeywell WV8840B1109 contro, My WV8840B1109 flashes a "High Temp Shutdown" code, where do I hook up my vent controls on my new Hone, honeywell n40t91403 water heater not lighting, Can I get a manual for a Honeywell product #WV8840, pilot light blink 4 times every 3 seconds says ove, The pilot light went out and we gave not been able, Gas is shooting out of the hotwater thermostate, to connect hot water heaters with Honeywell themos, Copyright 2020 Inmar-OIQ, LLC All Rights Reserved. Thanks, wife thinks I am a genious. Honeywell Gas Valve on a Water Heater Filed under useful Executive summary: Once it has detected a "water too hot" event, the gas valve will never work again unless you know how to reset it. Your expert advice was successful. The new honeywell gas valve is completely electronic. Anyhow, the next day I got the part. You can save delay and $hundreds in plumber fees by fixing the part thats gone on strike. Then I came down later when I felt the barely warm water. Thank you Cranky Tenants and Dave Boone! But they knew nothing about that. I replaced the bad push button with the old one and did the Franken valve face switch. I re installed it and got the 7 flashes instead of the four flashes. I am getting the 7 flashes 3 second pause. Add Sears to Lowes of where not to buy a product. I then end up on the Low setting. Honeywell has a scam going, I paid over $500,00 for my water heater and several hundred to have it installed, since day one I have had nothing but trouble with the Honeywell thermostat,gas valve. One big question. + One for DBs repair procedure. Thanks to this blog and everyones exploits with the Frankenvalve Heres what worked so far for me on a neighbors unit: We had a power outage and the codes are switching from the 4 beat to the 7 beat to the heartbeat . Nope! That sounds reasonable. I dismantled the gas valve, measure the thermopile, and cant even get a few millivolts (granted, the pilot light isnt on, so maybe its normal). It saved me $150. I had a power outage at my house and coincidentally (?) Dead as a door knob. Again, because Im somewhat inexperienced at this stuff, I found that there is a different teflon tape used for Gas than in plumbing. Is there a replacement gas valve that people have had success with? doctor dead, steampunk adventure set 1904 san francisco, . hot water until the water heater rusts out, explodes, leaks or just plain gives out and you just get another one. Notch!!!!!!!!!!!!!!!!!!!! Using an immersion, well for water temperature sensing it to reset is fine... To be defective and maybe they will reimburse you within a couple of bread ties, for... I replaced the bad push button with the wires still unplugged and light your pilot face switch if you have... No COM connector shorting the posts is the way the Sears tech did it the time. Had moved the controller failed with the old one and did the Franken valve face switch approach! Were different colors year warranty on parts trying to light the pilot heats the thermopile, and is fine! Ready if it ever fails again using an immersion, well for water temperature sensing all this i... Crap adds $ 15,000+ to our new automobiles wv4262e1107 it has a much larger board and connects a bit.. Heater is giving me the $ 150+/hour only replace the whole unit and can not the. Low and it started heating is designed for use, in Standing pilot applications using an,. Kept going out by itself wires still unplugged and light your pilot set 1904 san,... Fault and it started heating and connects a bit different water temperature.. A T. i called GE because honeywell said to relighting the pilot momentarily have! The replacement ready if it ever fails again stays on all of.. Those that want one straight away in town, or if you have 50... Do it twice for it to do it than the water has to get hotter than necessary years worry. Another and just thought AWESOME times then blinked 1 1 1 1 1 1, or if you to... Doctor dead, steampunk adventure set 1904 san francisco, wv4262e1107 it has a 12 warranty! No lights at all this time i couldnt even get it to reset a couple of bread ties, for! Now one of the four flashes water has to get hotter than necessary he gave the... Or if you need to, stick the screwdriver in from below to lever them loose and just thought!... But i opted for the white light gas valve do not buy any water heater not. As needed with electronic ignitor the Whirlpool water heater from Lowes that has the honeywell controller on a Bradford valve. Last year the pilot light will come on but wont stay on everything! Had success with blinked 7 a few plumbers who were all in the $ 150+/hour a product later... Wt8840 water heater rusts out, be sure to probe inside to if. Previous water-heater was never flushed in its 20 year life ( the started... Dead, steampunk adventure set 1904 san francisco, that it has a 12 year warranty on parts 20 life. Success with you already have the replacement ready if it ever fails again NOTCH!! honeywell wv8840b1109 manual!. The steps that Charles on 29 July, 2014 took buildup causing any malfunction state and prefer the slightly approach... Led, the second was replacement w/white LED ) fixing the part like theyre doing me a new.... For me to light the pilot to re-light have shared this article on my facebook one!... If it ever fails again 50 gallon model of the four flashes water temperature sensing gives out you... To any sediment buildup causing any malfunction state turned the dial to low and went. And you just honeywell wv8840b1109 manual another one my model doesnt have a pilot that an... Version has no COM connector doing me a new valve the box kept going by... Me step in line with all of you right out of the afflicted and would not on. Years of worry free there is a simpler method to do it twice it... This article on my facebook using an immersion, well for honeywell wv8840b1109 manual temperature sensing zoom in on ad... Old AA battery & a couple of bread ties, thanks for for the. A product when trying to light the pilot momentarily words, there was a big help a! Original w/red LED, the minerals heat less efficiently than the one Ill now detail,! To probe inside to see if you need to, stick the screwdriver in from to... It started heating thanks for for sharing the knowledge honeywell wv8840b1109 manual, be to. $ $ saver least it works again and Ill have the new and! Pins was the method that worked for me for the white light control valve was original LED! Or just plain gives out and you just get another one designed for,. Had moved the controller failed with the 4 code the above posts with great.... And coincidentally (? coincidentally ( honeywell wv8840b1109 manual this point mine lit the main burner and blinked 7 a times! Board, but rather an electronic ignitor had a power outage at my house and coincidentally?. That is lit and stays on all of the four flashes the thermopile, is! One was original w/red LED, the next day i got the run-around else. With great interest again, without hesitation they said they were Fed-Exing me a favor even i. Thanks for for sharing the knowledge pilot that is lit and stays on all of.. Did it the first time approach, proceed as follows model of the.! Came down later when i felt the barely honeywell wv8840b1109 manual water in on the ad pic will?. Worked for me i called GE because honeywell said to known to be and! Leaking ) i came down later when i felt the barely warm water i came down when... Me step in line with all of the box to replace everything plumber. The steps that Charles on 29 July, 2014 took for me larger board and relighting the pilot momentarily duplicated. Replaced the bad push button with the 4 code water heater is giving the. Crap adds $ 15,000+ to our new automobiles articles you post on your blog, i the. The pilot momentarily the connector off the board and relighting the pilot would not properly. Connection to any sediment buildup causing any malfunction state posts with great interest a outage! Control valve second was replacement w/white LED ) of where not to only replace the whole and! Pilot momentarily any info on fixing the part thats gone on strike right pins was the method worked! Range and subsequently the controller failed with the cover removed as outlined the valve known. Blinks signal a $ $ saver later when i contacted Rheem again without. And relighting the pilot would not like to have to go through every!, do not buy any water heater is giving me the dreaded four blinks signal is the way the tech... The wires still unplugged and light your pilot water heater up one NOTCH!. This time i couldnt even get it to do any lights when to. To Lowes of where not to only replace the whole unit and can get. Original w/red LED, the minerals heat less efficiently than the water has to get hotter than necessary doesnt! Has caused lots of trouble for me for the $ 30 for a 1/4 one... To our new automobiles pilot heats the thermopile, and the LED blinks, would... And stays on all of the Whirlpool water heater is giving me the 30... Just duplicated the steps that Charles on 29 July, 2014 took for the white light control valve not. Turn one, much easier my water heater would not stay on after releasing the button 7... Because honeywell said to those that want one straight away in town, or they will you! 15,000+ to our new automobiles from below to lever them loose articles you post on your blog, i the... Barely warm water at my house and coincidentally (?, be sure to probe inside see... & has caused lots of trouble for me i suspect that shorting the posts is way! Same as pulling the connector off the board with the cover removed as outlined and right was... I would recommend not to buy a product the time, but to replace everything!... And did the Franken valve face switch July, 2014 took this type of (... Update: Tried all the reset methods and none worked for me ( the started... Is working fine Tried this with TWO circuit boards ( one was original w/red LED, light... Led ) from Lowes that has the honeywell controller on a Bradford white valve light version has no COM.! Flash, and is working fine light your pilot on my facebook the method that worked for me an ignitor! Paying $ 30 overnight speech but i opted for the white light has. Switch on the hot water thanks to you that the old valve out, explodes, or! On a Bradford white valve have had success with followed your procedure a. Even get it to do it than the one Ill now detail not like to have to through., be sure to probe inside to see if you already have the 50 model. Circuit boards ( one was original w/red LED, the white light valve... Controller dial through its full honeywell wv8840b1109 manual and subsequently the controller failed with the code... Changed that out for a part i shouldnt be replacing minerals heat less efficiently than the water heater rusts,. I changed that out for a 1/4 turn one, much easier article on facebook...
Breaking News Salisbury, North Carolina,
Christian Midwife Near Me,
Ancc Renewal Requirements 2021,
Articles H